This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Dimensional
Dimensional
Accredited Capabilities
Global Calibration Scope
Gauge blocks: up to 20°
Thread plugs: up to 10°
Thread and plan plug gauges: up to 10°
Thread rings: up to 4°
Plan ring: up to 10°
Common equipment serviced: Thread plugs, Thread rings, Plan ring, Plan plug, Pin Gauges, Gauge blocks, NPT thread plugs and rings, Length standards
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Electricity
Electricity
Accredited Capabilities
Global Calibration Scope
DC voltage measure: up to 10kV
DC voltage generate: up to 1100V
DC current measure: up to 300A
DC current generate: up to 1025A W/COIL
Resistance generate: up to 100GOHM
Common equipment serviced: Power supplies, Hypots, Multimeters, Oscilloscopes, Resistors, Clamp meters, Shunts
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Force
Force
Accredited Capabilities
Global Calibration Scope
Up to 120KLBS
Common equipment serviced: Load cells, Force gauges, Hanging dynometers, Crane scales, Aircraft scales
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Hardness
Hardness
Accredited Capabilities
Global Calibration Scope
Durometer calibration per ASTM D2240
Common equipment serviced: Durometers
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Humidity
Humidity
Accredited Capabilities
Global Calibration Scope
10 to 95% RH
Common equipment serviced: Temperature humidity meters, Temperature humidity probes
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Mass / Scale
Mass / Scale
Accredited Capabilities
Global Calibration Scope
Scales: 0-500lbs
Balances: 0-10kg
Common equipment serviced: Balances, Scales
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Pressure / Vacuum
Pressure / Vacuum
Accredited Capabilities
Global Calibration Scope
Hydraulic: up to 10000 PSI
Pneumatic: up to 3000PSI
Common equipment serviced: Pressure gauges, Vacuum gauges, Pressure transducers
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Temperature
Temperature
Accredited Capabilities
Global Calibration Scope
Blackbody: -15 to 500°C
Temperature measure: -200 to 955°C
Common equipment serviced: Infrared thermometers, RTD sensors, Thermocouples, Temperature probes, Temperature measure, Oven, Furnace, Environmental chamber
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Torque
Torque
Accredited Capabilities
Global Calibration Scope
Up to 2000 ft-lbs for wrenches and transducers
Common equipment serviced: Torque wrenches, Torque transducers, Torque screwdrivers
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Time / Frequency
Time / Frequency
Accredited Capabilities
Global Calibration Scope
Timometer
GPS system
Common equipment serviced: Stopwatches, Times, Frequency counters
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Accelerometry
Global Calibration Scope
Accelerometer calibration from 5Hz-10kHz
Common equipment serviced: Accelerometers
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Dimensional
Global Calibration Scope
Gauge blocks: up to 20°
Thread plugs: up to 10°
Thread and plan plug gauges: up to 10°
Thread rings: up to 4°
Plan ring: up to 10°
Common equipment serviced: Thread plugs, Thread rings, Plan ring, Plan plug, Pin Gauges, Gauge blocks, NPT thread plugs and rings, Length standards
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Electricity
Global Calibration Scope
DC voltage measure: up to 10kV
DC voltage generate: up to 1100V
DC current measure: up to 300A
DC current generate: up to 1025A W/COIL
Resistance generate: up to 100GOHM
Common equipment serviced: Power supplies, Hypots, Multimeters, Oscilloscopes, Resistors, Clamp meters, Shunts
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Force
Global Calibration Scope
Up to 120KLBS
Common equipment serviced: Load cells, Force gauges, Hanging dynometers, Crane scales, Aircraft scales
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Hardness
Global Calibration Scope
Durometer calibration per ASTM D2240
Common equipment serviced: Durometers
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Humidity
Global Calibration Scope
10 to 95% RH
Common equipment serviced: Temperature humidity meters, Temperature humidity probes
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Mass / Scale
Global Calibration Scope
Scales: 0-500lbs
Balances: 0-10kg
Common equipment serviced: Balances, Scales
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Pressure / Vacuum
Global Calibration Scope
Hydraulic: up to 10000 PSI
Pneumatic: up to 3000PSI
Common equipment serviced: Pressure gauges, Vacuum gauges, Pressure transducers
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Temperature
Global Calibration Scope
Blackbody: -15 to 500°C
Temperature measure: -200 to 955°C
Common equipment serviced: Infrared thermometers, RTD sensors, Thermocouples, Temperature probes, Temperature measure, Oven, Furnace, Environmental chamber
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Torque
Global Calibration Scope
Up to 2000 ft-lbs for wrenches and transducers
Common equipment serviced: Torque wrenches, Torque transducers, Torque screwdrivers
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Time / Frequency
Global Calibration Scope
Timometer
GPS system
Common equipment serviced: Stopwatches, Times, Frequency counters
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
This browser is not actively supported by Microsoft anymore. To make sure you're able to use all features, switch to a compatible web browser such as Google Chrome, Mozilla Firefox, Microsoft Edge, or Safari.